project report tiger
Active In SP

Posts: 1,062
Joined: Feb 2010
15-02-2010, 12:41 PM

.ppt   Cryo-Tracker Level Temperature and Mass Gauging Fluid Sensors.ppt (Size: 164 KB / Downloads: 182)
Commercial Applications

Cryogenic storage and transport tanks
Home oxygen vessels
Medevac helicopter and military field hospital oxygen-generating systems
Automobiles running on liquid hydrogen or liqufied natural gas
summer project pal
Active In SP

Posts: 308
Joined: Jan 2011
11-01-2011, 11:22 PM

Cryo-Tracker Level, Temperature, and Mass Gauging Fluid Sensors

.ppt   Cryo-Tracker.ppt (Size: 164 KB / Downloads: 89)

Behavior of Sub-cooled Propellants in Room Temp.
Fig: Liquid Nitrogen unloaded from a small a Dewar Flask to a bucket in a laboratory.
Dewar Flask
Fig: A 25 l liquid nitrogen laboratory Dewar flask.
Inner wall linings are silvered to reduce heat leakage.
Flexible Sensing Probe
Probe is made of series of polyimide layers of thickness 0.0254 mm.
Rakes made of stainless steel tubing, wire, and phenolic insulators weigh (6.70 g/cm).
Internal Structure of Cryo-Tracker
Silicon diode sensors incorporated with the probe.
Conductor Traces which constitute the rake of the temp- element

Installed Cryo-Tracker Probe
Cryo-Tracker probe 60 ft. long.
2.5 cm wide.
containing 26 silicon diode sensors.
It’s weight is less than 0.59 kg.
Stratification of Sub-cooled Propellants
The heat leak causes the propellant to warm and stratify due to natural buoyancy forces.
Initially designed for incorporating in the propellant vessels of reusable launch vehicles.
Purpose of Cryo-Tracker
For knowing the amount of propellant loaded in.
For knowing the liquid & ullage temperature.
For knowing liquid level.
Mass Gauging Method
The entire liquid and ullage temperature profile is first obtained.
Tank pressure can then be used to calculate a liquid density profile.
Liquid density profile is integrated over the known tank volume.
Dual-Purpose Probe.
Temperature measured using silicon diode sensors.
Liquid level detection accuracy is a function of the sensor spacing.
For 12 inch sensor spacing, the overall liquid level accuracy is ± 6 inches.
Consistent thermal response can be
seen between the sensing elements in
a dual-element probe when it’s thermal-cycled in liquid nitrogen.
Hot-Fire Test (anomaly condition)
The probe is also capable of measuring transient fluid temperature changes.
Figure : Tracking the rapid change in liquid oxygen temperature when warm gases injected into the tank mixed the contents.
Advantages of Cryo-Tracker
Operating Costs
Commercial Applications
Cryogenic storage and transport tanks
Home oxygen vessels
Medevac helicopter and military field hospital oxygen-generating systems
Automobiles running on liquid hydrogen or liqufied natural gas


Important Note..!

If you are not satisfied with above reply ,..Please


So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Tagged Pages: cryo can com loc es, cryogenic dewar vessel for liquid nitrogen seminar journals, cryo tracker full report, cryo tracker level temperature and mass gauging fluid sensors pdf report, cryogenic military applications ppt, cryo tracker report pdf, cryo tracker,
Popular Searches: mobile network tracker india, make sunlight tracker, ppt on cryo pelletization, cryo rolling ppt, cryo tracker full report, eye tracker, cryo cars ppt,

Quick Reply
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  robots in radioactive environment full report project report tiger 14 16,536 27-04-2015, 07:00 PM
Last Post: Guest
  Pistonless Pump for Rockets full report and ppt project topics 8 10,468 15-11-2014, 04:08 PM
Last Post: mkaasees
  DRAG REDUCTION IN SHIPS USING MICROBUBBLES TECHNOLOGY full report project report tiger 4 7,425 24-03-2014, 04:27 PM
Last Post: seminar project topic
  Testing Of Bearings on Sound and Vibration Quality full report seminar class 1 2,443 09-10-2013, 03:16 PM
Last Post: Guest
  machine gun full report project report tiger 3 5,614 08-10-2013, 07:04 PM
Last Post: pc-alert
  micromachining full report project report tiger 4 10,068 02-09-2013, 10:10 AM
Last Post: study tips
  SUSPENSION SYSTEM full report seminar topics 18 29,477 20-08-2013, 07:43 PM
Last Post: vishnuts
  Multi Air Engine Full Report study tips 0 479 18-06-2013, 04:00 PM
Last Post: study tips
  Full Report on Smart materials in Automobile study tips 0 665 06-06-2013, 04:52 PM
Last Post: study tips
  pulse detonation engine full report project report tiger 3 9,819 31-05-2013, 09:13 AM
Last Post: study tips