.doc   Design Details of hi-low cutoff.doc (Size: 47.5 KB / Downloads: 103)
The power line fluctuations and cut-offs causes damages to electrical appliances connected to the line. It is more serious in the case of domestic appliances like fridge and air conditioners. If a fridge is operated on low voltage, excessive current flows through the motor, which heats up, and get damaged.
The under/over voltage protection circuit with time delay presented here is a low cost and reliable circuit for protecting such equipments from damages. Whenever the power line is switched on it gets connected to the appliance only after a delay of a fixed time. If there is hi/low fluctuations beyond sets limits the appliance get disconnected. The system tries to connect the power back after the specific time delay, the delay being counted from the time of disconnection. If the power down time (time for which the voltage is beyond limits) is less than the delay time, the power resumes after the delay: If it is equal or more, then the power resumes directly.
This circuit has been designed, built and evaluated by me to use as a protector for my home refrigerator. This is designed around readily available semi-conductor devices such as standard bipolar medium power NPN transistor (D313/SL100/C1061), an 8-pin type 741 op-amp and NE555 timer IC. Its salient feature is that no relay hunting is employed. This draw back is commonly found in the proctors available in the market.
The complete circuit is consisting of various stages. They are: - Dual rail power supply, Reference voltage source, Voltage comparators for hi/low cut offs, Time delay stage and Relay driver stage. Lets now look at the step-by-step design details.
1. Dual rail power supply.
This is a conventional type of power supply as shown in Figure 1. The power is applied through the step-down transformer (230/12-0-12V/500mA). The DC proportional to the charging input voltage is obtained from bridge rectifier. Two electrolytic capacitors are there to bypass any spikes present. Bridge is capable of handling currents up to 1 Amp.
2. Low voltage cut off op-amp
Figure 2 shows the use of very common and easily available op-amp 741 as a comparator. The op-amp is available in TO-5 and DIP type packing.
In this ckt the zener diode D1 and it’s associated resistor R1 are connected to the non-inverting terminal (+ve) of 741 to give the suitable reference voltage. The DC voltage from the sensor is given to the inverting (-ve) terminal through pre-set R2.This is used to set the input level.
When the sensor input is less than Zener voltage the output from the Op-amp remains high and when it is greater than Zener voltage the output goes low. When the sensing voltage is equal to Zener voltage the output of the op-amp is approximately zero.
This phenomenon is used as a decision for switching the relay and to give cutoff in a low voltage situation.
3.High voltage cut off op-amp
Here the op-amp is used as a inverted amplifier. See Figure 3.Zener and resistor network gives reference voltage to the inverting terminal (-ve) of op-amp. Sensing voltage derived through the 10 K pre-set is given to the non- inverting (+ve) terminal and this sets the high level cut.
When the input DC from the sensor is less than Zener voltage the output of the op-amp is low and vice-versa. When the input DC voltage is equal to the zener voltage, the op-amps output is approximately zero.

Important Note..!

If you are not satisfied with above reply ,..Please


So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Tagged Pages: download ppt of high low voltage cutoff circuit, hi low cutoff circuit, time switch images with hi low cut off voltage, cutoff in 2012, ppt on high low voltage cutoff, high low voltage cutoff, seminar on voltage delay,
Popular Searches: kvpy cut off 2012, high low voltage cut off with delay alarm, automatic water cut off system, over under voltage cut off with on time delay project report pdf, high and low voltage cut off with time delay project abstract, which system should be there to cut off power automatically in wrapping machines, 12 0 12v transformer 500ma details,

Quick Reply
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  dynamic voltage restorer ppt jaseelati 0 256 15-01-2015, 02:48 PM
Last Post: jaseelati
  SINGLE PHASE AC VOLTAGE CONTROLLER WITH R & RL LOADS project girl 1 1,376 25-09-2014, 11:03 AM
Last Post: Michaelbog
  Low Memory Color Image Zero Tree Coding computer science crazy 3 3,496 07-03-2014, 04:30 PM
Last Post: seminar project topic
  Grid Voltage Regulation Utilizing Storage Batteries in PV Solar seminar ideas 7 7,476 10-01-2014, 04:27 PM
Last Post: seminar project topic
  harnessing high altitude wind power full report computer science topics 5 18,753 27-09-2013, 09:32 AM
Last Post: seminar projects maker
  To verify the characteristics of Low pass and High pass filter seminar projects maker 0 372 26-09-2013, 03:20 PM
Last Post: seminar projects maker
  PULSE WIDTH MODULATION TECHNIQUES FOR VOLTAGE –FED INVERTERS PPT seminar projects maker 0 793 24-09-2013, 04:41 PM
Last Post: seminar projects maker
  SECOND ORDER BUTTERWORTH - LOW PASS FILTER pdf seminar projects maker 0 294 13-09-2013, 02:39 PM
Last Post: seminar projects maker
  VOLTAGE SHUNT FEEDBACK AMPLIFIER seminar projects maker 0 404 13-09-2013, 02:33 PM
Last Post: seminar projects maker
  Effect of Voltage and Load Variations on Efficiencies of a Motor-Pump System Report seminar projects maker 0 535 12-09-2013, 12:39 PM
Last Post: seminar projects maker