.pdf   Silicon-Micromachined Neurochips for In Vitro Studies of Cultured Neural Networks.pdf (Size: 2.32 MB / Downloads: 96)
The design, fabrication and testing of a novel neurochip structure for extracellular stimulation and recording of cultured neural networks are presented. The neurochip has 16 neuron wells, spaced 100 µm apart, in a 4 x 4 array, which are fabricated on a 9 mm by 3 mm silicon membrane, 20-µm-thick. The fabrication of the chips involves photolithography and micromachining on both sides of the membrane, which is located at the bottom of a 500-µm-deep cavity. Experimentally, the biocompatibility has been demonstrated by culturing live neuron networks in the neurochips.
INTRODUCTION The dynamics of long-term synaptic interactions is thought to be a key problem in understanding brain function. The study of synaptic plasticity is now possible in vitro, due to advances in cell culture, which allow specific neuron types to be removed from an animal and grown in a biochemical environment similar to their original habitat for periods of months. As a result, studies of synapse formation and neurite outgrowth are much easier to perform on cultured neurons. In general, it is not easy to achieve long-term, two-way electrical connection with the cells [1]. Moreover, difficulties may arise if one would like to perform experiments on cultured neural networks, where simultaneous electrical connection with many neurons is required. As for establishing electrical connection with cells, one way is to impale a neuron by a glass electrode filled with electrolyte. Another similar technique, so called patch-clamp technique, is using a thin glass pipette of the proper shape to tightly seal against a cell membrane [2]. Both techniques are extremely sensitive to voltage changes and highly specific in spatial resolution, but they can damage the cell during experiments. Also, it is extremely difficult to use more than two electrodes simultaneously, because of the bulky manipulators required to maneuver the electrodes into the correct position. Another category of methods is to use extracellular electrodes that capacitatively measure the cell potential. Silicon micromachining has been used to make such microdevices. For example, Najafi and Wise [3] have laid a valuable foundation for silicon multielectrode probes. Regehr, Pine and Rutledge [4] have demonstrated novel diving board electrodes for cultured neuron study. The major advantages of these silicon electrodes are their small sizes and biocompatibility. However, using these microdevices requires physical movement of the devices to, or near to, target neurons in order to form neuronmicrodevice connections. There are major drawbacks such as a lack of reliable and precise potential measurement due to a small signal-tonoise ratio and a poor spatial resolution.

Important Note..!

If you are not satisfied with above reply ,..Please


So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Tagged Pages: neurochips ppt, ppt of neurochips,
Popular Searches: mechanical project studies, how neurochips work, fabrication of neurochips, in vitro ph count, seminar topic on tribal studies, bulk micromachined diaphragm pressure sensor ppt, general studies project,

Quick Reply
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  detection and localization of multiple spoofing attackers in wireless networks ppt jaseelati 0 257 17-01-2015, 02:52 PM
Last Post: jaseelati
  QoS in Cellular Networks Based on MPT computer science crazy 5 5,059 01-04-2014, 09:26 AM
Last Post: seminar project topic
  DEFENDING WIRELESS NETWORKS FROM RADIO INTERFERENCE ATTACKS pdf seminar projects maker 0 412 25-09-2013, 02:12 PM
Last Post: seminar projects maker
  FROM GSM TO LTE - AN INTRODUCTION TO MOBILE NETWORKS AND MOBILE BROADBAND seminar projects maker 0 421 23-09-2013, 04:56 PM
Last Post: seminar projects maker
  crystalline silicon solar cell Abstract seminar projects maker 0 440 13-09-2013, 02:59 PM
Last Post: seminar projects maker
  Wireless sensor networks… And zigbee PPT study tips 0 545 10-09-2013, 02:01 PM
Last Post: study tips
Last Post: study tips
  Autonomous Routing Algorithm for LEO/GEO Satellite Networks pdf study tips 0 398 20-07-2013, 04:57 PM
Last Post: study tips
  ATM Transport in Mobile Networks with Tellabs 8600 Managed Edge System pdf study tips 0 335 17-07-2013, 01:17 PM
Last Post: study tips
  HIGH CAPACITY NETWORKS PPT study tips 0 304 03-07-2013, 03:42 PM
Last Post: study tips