Zero power magnetic levitation using composite of magnetostrictive - piezoelectric ma
Thread Rating:
  • 0 Vote(s) - 0 Average
  • 1
  • 2
  • 3
  • 4
  • 5
seminar class
Active In SP

Posts: 5,361
Joined: Feb 2011
02-03-2011, 03:34 PM

presented by:

.pptx   niveeth.pptx (Size: 1.5 MB / Downloads: 56)
Zero power magnetic levitation using composite of magnetostrictive - piezoelectric materials
What is a composite?

• Composite for magnetic force control
• comparison
• Experiments
using composite only
using composite and electromagnet
Magnetic levitation
• Inverse magnetostrictive effect
• Joule loss
• Zero power consumption during stationary
• Control by the integral feedback
• What is a composite?
• Composite for magnetic force control
• Dimensions
• When voltage is increased with fixed gap,flux changes as in (b)
• Now the PZTs extends and reduces the compressive force on Terfenol-D
• Thus magnetic force increases
• Since flux is conserved increase of flux in terfenol cause decrease in the gap

• It consists of coil with large no of turns of winding requires large power supply with high voltage.
• The operation is accompanied with joule loss
• Even when equipped with permanent magnet,the zero power is only valid at equilibrium state.
• It does not require large power supply because stack PZTs provide maximum performance at rating voltage.
• Power supply should amplify the voltage,but does not have to be capable of providing large current.
• The composite does not consume electric energy in static operation at any value of force.This is due to capacitive property of PZTs.
• Levitation using composite
• Yoke equations
• F = Fo + dF= Fo + Kx *x +Kv*v
Kx-gradient of F with gap under fixed voltage
Kv-gradient of F with voltage under fixed gap
• Kinetic equation
mx·· +cx· +Kx*x +Kv*v =0
c-damping coefficient
• Combination of composite and electromagnet
Experimental set up

• Control voltage is fed to PZTs from gap sensor through dc-dc converter
• To electromagnet through current amplifier
• Converter is energized with a dry cell of 4.5v
By varying the gap stationary under the fixed mass, the control outputs for electromagnet and composite are
ic = Kpc *x + Kdc*x·+ Kic∫ic dt
vp= Kpp*x + Kip ∫x dt
• conclusion
• Experiments on levitation was conducted and the gap at the levitation was successfully controlled by the voltage of the PZTs
• It maintained zero power consumption in static state
• Composite can be used for large loads too
• Applications include high precision positioning and convey system
• reference
• T. Ueno, J. Qiu, and J. Tani, “Magnetic force control based on the inverse magnetostrictive effect,” IEEE Trans. Magn., vol. 40, no. 3, pp.1601–1605, May 2004.
• T. Ueno, J. Qiu, and J. Tani, “New magnetic force control device with composite of giant magnetostrictive and piezoelectric materials,” IEEE Trans. Magn., vol. 39, no. 6, pp. 3534–3540, Nov. 2003.
• T. Ueno and T. Higuchi, “Design of magnetostrictive/piezoelectric laminate composite for coil-less magnetic force,” IEEE Trans. Magn. vol. 41, no. 4, pp. 1233–1237, Apr. 2005.
• T. Ueno and T. Higuchi, “Zero-power magnetic levitation by magnetic force control device using lamination of magnetostrictive material and piezoelectric material,” in Ninth Int. Symp. Magnetic Bearings, 2004.

Important Note..!

If you are not satisfied with above reply ,..Please


So that we will collect data for you and will made reply to the request....OR try below "QUICK REPLY" box to add a reply to this page
Tagged Pages: magnetic levitation force calculation, terfenop d in magnetic levitation, 5360 4 5v dry cell,
Popular Searches: electricity using agnetic levitation, magnetic levitation trains pictures, levitation, electro magnetic levitation explains of control circuit, magnetic levitation based major projects, spin stabilized magnetic levitation, magnetic levitation trains in germany,

Quick Reply
Type your reply to this message here.

Image Verification
Please enter the text contained within the image into the text box below it. This process is used to prevent automated spam bots.
Image Verification
(case insensitive)

Possibly Related Threads...
Thread Author Replies Views Last Post
  detecting power grid synchronization failure jaseelati 2 344 20-05-2016, 12:28 PM
Last Post: Dhanabhagya
  electric rail cars often use magnetic braking. jaseelati 1 768 28-11-2015, 12:53 PM
Last Post: Guest
  FLEXIBLE POWER ELECTRONIC TRANSFORMER seminar tips 2 1,585 05-07-2015, 09:58 AM
Last Post: tunhtutaye
  electronic power generator using transistor jaseelati 0 325 31-01-2015, 01:52 PM
Last Post: jaseelati
  floating power plant ppt jaseelati 0 312 31-01-2015, 12:49 PM
Last Post: jaseelati
  inductive power transfer ppt jaseelati 0 248 23-01-2015, 02:21 PM
Last Post: jaseelati
  power theft detection via plc pdf jaseelati 0 323 22-01-2015, 03:31 PM
Last Post: jaseelati
  distributed power flow controller ppt jaseelati 0 258 21-01-2015, 03:21 PM
Last Post: jaseelati
  wireless power theft monitoring system and indication at local substations. jaseelati 0 345 10-01-2015, 03:42 PM
Last Post: jaseelati
  pedal power hacksaw project report jaseelati 0 295 10-01-2015, 02:14 PM
Last Post: jaseelati